Назва: | Influence of the shape and geometric parameters of clasps on the strength and holding force of removable orthopedic dentures |
Автори: | Bogdanov, V. Grigorenko, A. Sorochenko, G. Tormakhov, N. |
Ключові слова: | Removable partial dentures, shape of a clasp, thermoplastics, internal forces, stresses. |
Дата публікації: | 2023 |
Короткий огляд (реферат): | We propose a procedure for the evaluation of the characteristics of clasps of removable partial dentures made of thermoplastic materials. The procedure includes the following stages: evaluation of the specific pressure of a clasp on the retaining tooth, determination of the maximum internal forces and stresses in the clasp, and finding its shape in the unloaded state. The results of our investigations enable us to choose the optimal sizes of the clasp in order to create the required holding force for the denture with guaranteeing its sufficient strength |
URI (Уніфікований ідентифікатор ресурсу): | http://ir.librarynmu.com/handle/123456789/14858 |
ISSN: | UDC 539.3, 617.3 |
Розташовується у зібраннях: | Наукові публікації кафедри дитячої терапевтичної стоматології та профілактики стоматологічних захворювань |