Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://ir.librarynmu.com/handle/123456789/7620
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorMarushko, Y.-
dc.contributor.authorKhomych, O.-
dc.date.accessioned2023-05-19T10:36:48Z-
dc.date.available2023-05-19T10:36:48Z-
dc.date.issued2023-
dc.identifier.citationMarushko YuV, Khomych OV. (2023). Assessment of acoustic signal characteristics in children with community-acquired pneumonia according to the prevalence and nature of lung tissue damage using the new device «Trembita-Corona». Modern Pediatrics. Ukraine. 2(130): 79-88. doi 10.15574/SP.2023.130.79.uk_UA
dc.identifier.issn2663-7553-
dc.identifier.urihttp://ir.librarynmu.com/handle/123456789/7620-
dc.description.abstractRelevance. According to the new orders and guidelines of 2022, radiography is not performed for all children. Therefore, the creation of a fully automated system of control and assessment of breathing sounds, without exposing patients to radiation, is currently an urgent task. Purpose – to determine the features of the acoustic signal in segmental and focal pneumonia in children with a new acoustic diagnostic device “Trembita-Corona”. Materials and methods. 76 children aged from 1 month to 18 years were examined. The children were divided into two groups: the Group 1 – 47 patients with segmental pneumonia; the Group 2 – 29 patients with focal pneumonia. All children were also examined using the “Trembita-Corona” acoustic monitoring device. Results. The acoustic signal was investigated in 12 octaves. The first 9 octaves were the most promising. Each octave was divided into third octaves. We found reliable differences in the average signal power in 0, 1, 4, 6, 7, 15, 20, 23-26 third octaves. When studying the average signal power between children with segmental and focal pneumonia, the main differences were found precisely in the frequency of peaks in 0-3,10,11,14-16, 18,20,22 third octaves. Conclusions. The use of the acoustic monitoring device “Trembita-Corona” in making a diagnosis is very promising method. The average signal power between children with segmental and focal pneumonia, the main differences were found precisely in the frequency of peaks in 0, 1, 2, 3, 10, 11, 14, 15, 16, 18, 20, 22 third octaves. The research was carried out in accordance with the principles of the Helsinki Declaration. The study protocol was approved by the Local Ethics Committee of all participating institutions. The informed consent of the patient was obtained for conducting the studies. No conflict of interests was declared by the authors.uk_UA
dc.publisherСучасна педіатрія. Українаuk_UA
dc.relation.ispartofseriesСучасна педіатрія. Україна;№2 (130)-
dc.subjectacoustic monitoringuk_UA
dc.subject“Trembita-Corona” deviceuk_UA
dc.subjectcommunity-acquired pneumoniauk_UA
dc.subjectfocal pneumoniauk_UA
dc.subjectsegmental pneumoniauk_UA
dc.subjectchildrenuk_UA
dc.titleAssessment of acoustic signal characteristics in children with community-acquired pneumonia according to the prevalence and nature of lung tissue damage using the new device «Trembita-Corona»uk_UA
dc.typeArticleuk_UA
Розташовується у зібраннях:Наукові публікації кафедри педіатрії післядипломної освіти

Файли цього матеріалу:
Файл Опис РозмірФормат 
12-1.pdf200,63 kBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.